Part Number Hot Search : 
MA5120 IDM37SH5 AF28TC 512K32 XC6206P 2N60C P3000 CL1503
Product Description
Full Text Search
 

To Download TFS70H17 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 File name: TFS70H17.doc
Version 1.0
20.02.2002
VI TELEFILTER
Filter specification
TFS 70H17
1/5
1. Measurement condition :
Ambient temperature TA: Input power level: Terminating impedances in fc: 25 C. 0 dBm. for input: for output:
50 50
0 pF. 0 pF.
2. Characteristics :
Remark: Reference level for the relative attenuation a rel of the TFS 70H17 is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation a min is defined as the insertion loss ae . The reference frequency fc is the arithmetic mean value of the upper and lower frequencies at the 20 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference frequency f c and the frequency response of the filter in the operating temperature range. The frequency shift of the filter in the operating temperature range is not included in the production tolerance scheme.
Data
Insertion loss (Reference level) Centre frequency Pass band ( PB ) : Amplitude ripple in : Bandwidth ( BW ) : 1 dB 3 dB 20 40 50 dB dB dB fc - 4,5 MHz ... fc + 4,5 MHz at ambient temperature TA ae
typ. value 25,5 dB 70,0 MHz
tolerance / limit max. 70,0 26 dB
fc at ambient temperature (fCTA)
0,10 MHz
fc ... fc 5,0 MHz 0,7 dB 9,99 MHz 10,35 MHz 11,31 MHz 11,78 MHz 11,93 MHz 50 55 58 dB dB dB max. min. min. max. 1 dB
9,0 MHz 10,0 MHz 12 MHz
Relative attenuation arel fc ... fc 4,5 MHz fc 4,5 MHz ... fc 5,0 MHz fc 6 MHz ... fc 7 MHz fc 7 MHz ... fc 14 MHz fc 14 MHz ... fc 30 MHz Group delay ( mean value in PB ):2,09 Group delay ripple in PB (p-p): Deviation from linear phase in PB : Triple transit attenuation compared to main signal Crosstalk Temperature coefficient of frequency ( Tcf ) : Frequency deviation of f c over temperature : Operating temperature range Storage temperature range
max. max. min. min. min. max. max. max.
1 3 40 48 50
dB dB dB dB dB
2,2 s 50...65 ns 3,3 (r.m.s. 0,7 ) 60 70...75 dB dB
2,5 s 70 ns 4 p-p
-87 ppm/K fc(Hz) = Tcf(ppm/K) x (T - T o) x fCTA (MHz) - 25 C ... + 80 C - 40 C ... + 85 C
Generated:
Checked/Approved:
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File name: TFS70H17.doc
Version 1.0
20.02.2002
VI TELEFILTER
Filter specification
TFS 70H17
2/5
3. Construction and pin connection
( all dimensions in mm)
22,5 Max. 5,0 max.
13 max.
5,6 max. 2,54 0,2 6x2,54 = 15,62
0,45 Dia.
7,62
TFS
70H17 P22
Date-code: M N P ...
Date-code
Year+week 2000 2001 2002 ...
1
2
7 Pin Pin Pin Pin Pin 14 1 8 7 2, 9 Input Input RF Return Output Output RF Return Pakage Ground
14
9
8
4. 50
matching networks ( please refer to the application note for further details ) :
1
2
7
50 14 9 8
50
.
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File name: TFS70H17.doc
Version 1.0
20.02.2002
VI TELEFILTER
Filter specification
TFS 70H17
3/5
5. Stability characteristics :
After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 - 14 Test N
2. Vibration:
3. Change of temperature:
4. Resistance to solder heat (reflow):
reflow possible: twice max.; for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4;
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File name: TFS70H17.doc
Version 1.0
20.02.2002
VI TELEFILTER
Filter specification
TFS 70H17
4/5
6. Air reflow temperature conditions :
1st and 2nd air reflow profile
Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C
Chip-mount air reflow profile
260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240
Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File name: TFS70H17.doc
Version 1.0
20.02.2002
VI TELEFILTER
7. History :
Version 1.0 Reason of changes Generate filter specification.
Filter specification
TFS 70H17
5/5
Name Steiner.
Date 20.02.2002
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.


▲Up To Search▲   

 
Price & Availability of TFS70H17

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X